Model A15/82
Fluoride Monitor
Home Office European Office
Analytical Technology, Inc. ATI (UK) Limited
6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park
Collegeville, PA 19426 Delph New Road, Delph
Saddleworth OL3 5DE
Ph: (800) 959-0299 Ph: 0800-018-4020
(610) 917-0991 + 44 (0) 1457-873-318
Fax: (610) 917-0992 Fax: + 44 (0) 1457-874-468
Email: sales@analyticaltechnology.com Email: sales@atiuk.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1

Model A15/82 Fluoride Monitor Home Office European Office Analytical Technology, Inc. ATI (UK)

Strany 2 - PRODUCT WARRANTY

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 9 O&M Manual Rev-G (6/10) The optional NEMA 4X wall mount enclosure is a molded plasti

Strany 3

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 10 O&M Manual Rev-G (6/10) The chemistry module contains the components required to con

Strany 4 - TABLE OF FIGURES

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 11 O&M Manual Rev-G (6/10) SAMPLE INLET OVERFLOW The water sample supplied to the mo

Strany 5 - UNPACKING

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 12 O&M Manual Rev-G (6/10) BUFFER AND CALIBRATION STANDARD BOTTLE HOLDERS Two bottle

Strany 6 - INTRODUCTION

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 13 O&M Manual Rev-G (6/10) REAGENT AND FLUORIDE STANDARD PICKUP TUBING CONNECTION A

Strany 7

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 14 O&M Manual Rev-G (6/10) ELECTRICAL CONNECTIONS Wiring connections to the A15/82 are

Strany 8 - SPECIFICATIONS

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 15 O&M Manual Rev-G (6/10) The fluoride chemistry module requires AC power for operati

Strany 9 - INSTALLATION

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 16 O&M Manual Rev-G (6/10) START-UP Prior to operation, recheck electrical connect

Strany 10

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 17 O&M Manual Rev-G (6/10) FRONT PANEL LOCK The key switches on the front panel of th

Strany 11

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 18 O&M Manual Rev-G (6/10) CONFIGURATION The electronics for the Fluoride system are de

Strany 12

PRODUCT WARRANTY Analytical Technology, Inc. (Manufacturer) warrants to the Customer that if any part(s) of the Manufacturer's products pr

Strany 13

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 19 O&M Manual Rev-G (6/10) 9. SET A F.: LO (OR HI) This routine allows the function

Strany 14

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 20 O&M Manual Rev-G (6/10) 20. CALIBR. T: 3.0’ This routine specifies the amount of

Strany 15 - ELECTRICAL CONNECTIONS

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 21 O&M Manual Rev-G (6/10) CHEMISTRY MODULE STARTUP After mechanical and electrical ins

Strany 16

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 22 O&M Manual Rev-G (6/10) AUTOMATIC CALIBRATION VALVE A 2-way pinch valve is mounted

Strany 17 - START-UP

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 23 O&M Manual Rev-G (6/10) OPERATION With the chemistry module in operation and power

Strany 18

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 24 O&M Manual Rev-G (6/10) for the glass electrode and -405 mV for the polymer sensor).

Strany 19 - CONFIGURATION

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 25 O&M Manual Rev-G (6/10) AUTOMATIC CALIBRATION The A15/82 Fluoride Monitor performs

Strany 20

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 26 O&M Manual Rev-G (6/10) FLUORIDE CALIBRATION STANDARD The automatic calibration ro

Strany 21

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 27 O&M Manual Rev-G (6/10) CONTROL & ALARM OUTPUTS The Fluoride Monitor is equippe

Strany 22 - CHEMISTRY MODULE STARTUP

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 28 O&M Manual Rev-G (6/10) ALARM RELAY The A15/82 contains a relay designated as an al

Strany 23

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 2 O&M Manual Rev-G (6/10) TABLE OF CONTENTS UNPACKING ...

Strany 24 - OPERATION

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 29 O&M Manual Rev-G (6/10) MAINTENANCE The A15/82 Fluoride Monitor will generally provi

Strany 25

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 30 O&M Manual Rev-G (6/10) 3. Replacement tubes are precut to the proper length. For ac

Strany 26

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 31 O&M Manual Rev-G (6/10) SPARE PARTS - MODEL A15/82 PART NO. DESCRIPTION 00-12

Strany 27

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 3 O&M Manual Rev-G (6/10) TABLE OF FIGURES Figure 1 - Fluoride Monitoring System ...

Strany 28 - CONTROL & ALARM OUTPUTS

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 4 O&M Manual Rev-G (6/10) UNPACKING When you receive your Fluoride Monitor, open the

Strany 29

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 5 O&M Manual Rev-G (6/10) INTRODUCTION The Model A15/82 is an on-line monitoring syst

Strany 30 - MAINTENANCE

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 6 O&M Manual Rev-G (6/10) Figure 1 - Fluoride Monitoring System

Strany 31

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 7 O&M Manual Rev-G (6/10) SPECIFICATIONS ELECTRONIC MONITOR Range: 0-1.00 PPM

Strany 32 - SPARE PARTS - MODEL A15/82

ATI Model A15/82 Fluoride Monitor with Auto-Calibration 8 O&M Manual Rev-G (6/10) INSTALLATION The main installation requirements for the ATI

Komentáře k této Příručce

Žádné komentáře